McCrometer MX Magmeter
Flow Range 0.75 to 35 ft/sec
Nominal Pressure 150 PSI, 300 PSI optional
Tube Material Stainless Steel (SS 304)
Measuring Electrodes SS 316, Monel, hastelloy C, Tantalum, Titanium
Flanges Carbon Steel, stainless steel
Flange Pattern AWWA, ANSI, DIN, BST
Tube Lining Temp Limits PTFE (300 F) Polyurethane (120 F) Hard Rubber and Neoprene (160 F) Ebonite (200 F)
Abient Temp 10 to 120 degrees F
Min Fluid Conductivity 5 micro Siemens/cm
Outputs 4 to 20 mA into 750 ohms maximum (isolated), Active 24 V pulse for electromechanical totalizer
Repeatability +/- 0.1% of rate
Accuracy +/- 0.5% of rate
Power Supply 24 volts DC, 110/220 volts AC (Tolerance +/- 10%)
Equip Protection Type Meter Body to NEMA 6P; Signal Converter to NEMA 4
Excitation Type AC and pulsed DC
Electronics Mounting 300 ft. maximum distance from meter
Meter & Nominal Pipe Size 1 1.5 2 3 4 6 8 10 12 14 16 18 20 24 28 30 32
Meter length 7.9 8.7 11.8 11.8 16.5 16.5 18.9 18.9 18.9 22.8 24.4 26.8 28.3 32.3 36.2 38.6 40.2
Meter height 10.5 10.8 12.2 13.4 14.4 16.5 18.9 21.1 23.2 25.6 28 30.3 33.1 37.6 42.7 45.1 47.4
Meter Width 6.3 6.7 8.1 9.1 10 12.2 14.6 16.7 19.1 21.3 23.6 26 28.7 33.3 38.4 40.7 43.1
Approx Weight (lbs) 22 26 44 51 59 92 132 176 220 308 418 484 616 924 1100 1232 1430

GREAT PLAINS METER INC.  (* consult factory)